Lamar Owen
 
Default RHEL-6 vs. CentOS-5.5 (was: Static assignment of, SCSI device names?)

On Wednesday, February 02, 2011 02:06:15 am Chuck Munro wrote:
> The real key is to carefully label each SATA cable and its associated
> drive. Then the little mapping script can be used to identify the
> faulty drive which mdadm reports by its device name. It just occurred
> to me that whenever mdadm sends an email report, it can also run a
> script which groks out the path info and puts it in the email message.
> Problem solved :-)

Ok, perhaps I'm dense, but, if this is not a hot-swap bay you're talking about, wouldn't it be easier to have the drive's serial number (or other identifier found on the label) pulled into the e-mail, and compare with the label physically found on the drive, since you're going to have to open the case anyway? Using something like:

hdparm -I $DEVICE | grep Serial.Number

works here (the regexp Serial.Number matches the string "Serial Number" without requiring the double quotes....). Use whatever $DEVICE you need to use, as long as it's on a controller compatible with hdparm usage.

I have seen cases with a different Linux distribution where the actual module load order was nondeterministic (modules loaded in parallel); while upstream and the CentOS rebuild try to make things more deterministic, wouldn't it be safer to get a really unique, externally visible identifier from the drive? If the drive has failed to the degree that it won't respond to the query, then query all the good drives in the array for their serial numbers, and use a process of elimination. This, IMO, is more robust than relying on the drive detect order to remain deterministic.

If in a hotswap or coldswap bay, do some data access to the array, and see which LED's don't blink; that should correspond to the failed drive. If the bay has secondary LED's, you might be able to blink those, too.
_______________________________________________
CentOS mailing list
CentOS@centos.org
http://lists.centos.org/mailman/listinfo/centos
 

Thread Tools




All times are GMT. The time now is 04:16 PM.

VBulletin, Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.
Content Relevant URLs by vBSEO ©2007, Crawlability, Inc.
Copyright 2007 - 2008, www.linux-archive.org